Home > Products > Honeywell solenoid valve > GK series > Honeywell standard solenoid valve for medium up to180 degree GK50F

Honeywell standard solenoid valve for medium up to180 degree GK50F

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.
Valve application: gaseous/liquid
Materials: Casing: (see below), either brass or cast iron GG25, Membrane: viton and graphit
Media temp.: 0...180C
Ambient temperature: 0...55C
Operating mode: normally closed
Power supply: 230V 50Hz
Working range: 0...10bar
Flanged version, material: cast iron GG25
DN size: 50mm
Kvs value: 36
Connections: flange
Honeywell standard solenoid valve for medium up to180 degree GK50

Honeywell standard solenoid valve for medium up to180 degree GK50


The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.Valve application: gaseous/liquidMaterials: Casing: (see below), either brass or cast iron GG25, Me
Honeywell standard solenoid valve for liquid medium-AB13

Honeywell standard solenoid valve for liquid medium-AB13


The 2/2-way valves of the AB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are
Honeywell solenoid valve(component tested) for neutral liquid medium-AV201MS2

Honeywell solenoid valve(component tested) for neutral liquid medium-AV201MS2


The 2/2-way valves of the AV-series are designed for safety function in liquid fuel supply systems. The valves prevent unintended draining of the system and storage tanks in case of malfunction of burner or filter.Valve application: fuel oilMaterials: Casing: brass Internal parts: stainless steel Me
Honeywell solenoid valve(component tested) for potable water AT10

Honeywell solenoid valve(component tested) for potable water AT10


The 2/2-way valves of the AT-series are suitable for potable water and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure.Valve application: liquidMaterials: Casing: brass Internal parts: stainless steel Membrane: EPDMMedia temp.: 0...12
Honeywell MS165 solenoid valve

Honeywell MS165 solenoid valve


MS: pilot operated, two way construction Normally closed Hermetic construction Low pressure drop High performance Direct operated: no minimum pressure differential required to open the valve Pilot operated: minimum pressure differential of 0.05 bar required to open the valve Solder a
Honeywell MD062 solenoid valve

Honeywell MD062 solenoid valve


MD: direct operated, two way construction Normally closed Hermetic construction Low pressure drop High performance Direct operated: no minimum pressure differential required to open the valve Pilot operated: minimum pressure differential of 0.05 bar required to open the valve Sol
Honeywell standard solenoid valve for medium up to180 degree GK32F

Honeywell standard solenoid valve for medium up to180 degree GK32F


The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.Valve application: gaseous/liquidMaterials: Casing: (see below), either brass or cast iron GG25, Me
Honeywell solenoid valve(component tested) for potable water AT50

Honeywell solenoid valve(component tested) for potable water AT50


The 2/2-way valves of the AT-series are suitable for potable water and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure.Valve application: liquidMaterials: Casing: brass Internal parts: stainless steel Membrane: EPDMMedia temp.: 0...12
Honeywell MA042MMS  solenoid valve

Honeywell MA042MMS solenoid valve


Kv-value 0.12 m3/h Maximum pressure PS 30 bar(a) Maximum test pressure PF 42.6 bar(a) Min. pressure differential 0 bar Max. opening pressure differential MOPD 25 bar Max. medium temperature 125 °C Min. medium temperature -45 °C Max. ambient temperature 80 °C Min. ambient temperature -40 Â
Honeywell standard solenoid valve for gaseous and liquid medium-GB20

Honeywell standard solenoid valve for gaseous and liquid medium-GB20


The 2/2-way valves of the GB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in
Honeywell solenoid valve(component tested) for potable water AT20

Honeywell solenoid valve(component tested) for potable water AT20


The 2/2-way valves of the AT-series are suitable for potable water and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure.Valve application: liquidMaterials: Casing: brass Internal parts: stainless steel Membrane: EPDMMedia temp.: 0...12
Honeywell standard solenoid valve for liquid medium-AB20

Honeywell standard solenoid valve for liquid medium-AB20


The 2/2-way valves of the AB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are
Please Complete the short form below and a A&S sales representatives will contact you shortly. Note: Fields labeled with a * are required.
* Product:
* First Name:
* Last Name:
* Company:
  Phone:
   Fax:
*  Email:
*  Inquiry / Comments
*  Code
 
page run: 1040.3 ms