Home > Products > Honeywell solenoid valve > Honeywell MA042 series > Honeywell MA042MMS solenoid valve

Honeywell MA042MMS solenoid valve

Kv-value 0.12 m3
/h
Maximum pressure PS 30 bar(a)
Maximum test pressure PF 42.6 bar(a)
Min. pressure differential 0 bar
Max. opening pressure
differential MOPD 25 bar
Max. medium temperature 125 °C
Min. medium temperature -45 °C
Max. ambient temperature 80 °C
Min. ambient temperature -40 °C
Standard coil voltages 230 V AC, 50 Hz, 8 W
Voltage tolerance ±10%
Honeywell standard solenoid valve for medium up to180 degree GK50

Honeywell standard solenoid valve for medium up to180 degree GK50


The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.Valve application: gaseous/liquidMaterials: Casing: (see below), either brass or cast iron GG25, Me
Honeywell standard solenoid valve for liquid medium-AB40

Honeywell standard solenoid valve for liquid medium-AB40


The 2/2-way valves of the AB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are
Honeywell standard solenoid valve for liquid medium-AB20

Honeywell standard solenoid valve for liquid medium-AB20


The 2/2-way valves of the AB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are
Honeywell standard solenoid valve for medium up to180 degree GK40

Honeywell standard solenoid valve for medium up to180 degree GK40


The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.Valve application: gaseous/liquidMaterials: Casing: (see below), either brass or cast iron GG25, Me
Honeywell solenoid valve(component tested) for potable water AT13

Honeywell solenoid valve(component tested) for potable water AT13


The 2/2-way valves of the AT-series are suitable for potable water and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure.Valve application: liquidMaterials: Casing: brass Internal parts: stainless steel Membrane: EPDMMedia temp.: 0...12
Honeywell MA042S  solenoid valve

Honeywell MA042S solenoid valve


Kv-value 0.12 m3/h Maximum pressure PS 30 bar(a) Maximum test pressure PF 42.6 bar(a) Min. pressure differential 0 bar Max. opening pressure differential MOPD 25 bar Max. medium temperature 125 °C Min. medium temperature -45 °C Max. ambient temperature 80 °C Min. ambient temperature -40 Â
Honeywell MD102 solenoid valve

Honeywell MD102 solenoid valve


MD: direct operated, two way construction Normally closed Hermetic construction Low pressure drop High performance Direct operated: no minimum pressure differential required to open the valve Pilot operated: minimum pressure differential of 0.05 bar required to open the valve Solder
Honeywell standard solenoid valve for medium up to180 degree GK32

Honeywell standard solenoid valve for medium up to180 degree GK32


The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.Valve application: gaseous/liquidMaterials: Casing: (see below), either brass or cast iron GG25, Me
Honeywell MS227 solenoid valve

Honeywell MS227 solenoid valve


MS: pilot operated, two way construction Normally closed Hermetic construction Low pressure drop High performance Direct operated: no minimum pressure differential required to open the valve Pilot operated: minimum pressure differential of 0.05 bar required to open the valve Solder and flare
Honeywell solenoid valve(component tested) for potable water AT32

Honeywell solenoid valve(component tested) for potable water AT32


The 2/2-way valves of the AT-series are suitable for potable water and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure.Valve application: liquidMaterials: Casing: brass Internal parts: stainless steel Membrane: EPDMMedia temp.: 0...12
Honeywell MS167 solenoid valve

Honeywell MS167 solenoid valve


MS: pilot operated, two way construction Normally closed Hermetic construction Low pressure drop High performance Direct operated: no minimum pressure differential required to open the valve Pilot operated: minimum pressure differential of 0.05 bar required to open the valve Solder a
Honeywell standard solenoid valve for gaseous and liquid medium-GB20VA

Honeywell standard solenoid valve for gaseous and liquid medium-GB20VA


The 2/2-way valves of the GB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in